1RWH

The total current available from the HW1&2 DC out terminal

is 250 mA at up to 120ºF (49ºC). A 24-hour battery standby for UL

requirements will be met with a maximum load of 250 mA.
With Hardwired Siren Supervision turned on, sirens connected to

HW1 I/O are supervised and require a 4.7-kohm resistor in the

circuit. If this terminal is not used, turn Hardwired Siren

Supervision off.

([WHULRUVLUHQV

For an exterior siren, reprogram HW1 to Option 6. See wiring

diagram.

1RWH

Not investigated for and may not be used in a UL Listed

installation.

+DUGZLUHGFRQWDFWV

You can connect hardwired reed switches (normally closed loop

only) to HW1 I/O (if not being used for a hardwired siren) an/or

HW2 in (terminal 3).
Connect only normally closed (NC) reed switches to HW1 I/O

and/or HW2 in. Other types of hardwired detectors should not be

used.
The total resistance of the wired loop must not exceed 3 ohms.

This allows you to use up to 200 ft. (61 m) of two-conductor, 22-

gauge stranded wire.
Connect hardwired reed switches to the panel using a 47-kohm

resistor (not a 4.7-kohm resistor) as shown in Figure 2 below.

The resistor must be connected at the last switch in the circuit.

)LJXUH1RUPDOO\FORVHGKDUGZLUHGUHHGVZLWFKHV

H

W

1 I/O

47 kohm resistors

HW

1

&

2

D

C

out

HW2

in

9V

A

C

i

n

9V

A

C

i

n

B

a

tter

y

+

B

a

tter

y

-

1RWH

Do not install the resistor at the panel terminals. This

does not provide supervision of the wire.

:LULQJSKRQHOLQHV

You can connect a phone line to the panel for systems monitored

by a central monitoring station or systems that notify users by a

voice event notification.
DSL (digital subscriber line) allows the use of multiple devices on a

single phone line simultaneously. For DSL environments, connect

the panel line-in jack to an available phone jack on the premises.

You might also need an inline filter to ensure panel reporting is

successful.

1RWH

Avoid connecting the panel to a standard phone (voice) line

in this manner. Other devices in use at the same time the panel is

using the line can prevent reports from going through.

)XOOOLQHVHL]XUH

Full line seizure allows the panel to take over (seize) the phone line,

even if another device on the line is in use. This method requires

that the panel be wired before all other phones, answering

machines, computers, or other devices on the phone line. You may

need to verify the line seizure for UL installations.
Use the RJ31X (CA-38A) jack when wiring for full line seizure. You

can then quickly and easily disconnect the panel from the phone

line in case the panel disables the phone line due to a malfunction.

7RZLUHIXOOOLQHVHL]XUHZLWKDQ5-;

1. Run a four-conductor cable from the premises Telco block to

the RJ31X.

2. Connect

the

four-conductor cable wire to the RJ31X.

3. Disconnect the green and red premises phone jack wires

from the Telco block and splice them to the four-conductor

cable black and white (or yellow) wires. Use weatherproof

wire connectors for these splices.

4. Connect the four-conductor cable green and red wires to the

Telco block TIP (+) and red to RING (-) posts.

5. Connect the phone cord included with the panel to the RJ31X

and the panel LINE jack.

)XOOOLQHVHL]XUHZLULQJZLWKRQHSUHPLVHVSKRQH

If a single phone is all that exists on the premises, full line seizure

can be accomplished without an RJ31X.
1. Disconnect the phone from the premises phone jack and plug

it into the panel PHONE jack. This jack is disconnected

automatically whenever the panel reports.

2. Connect the included phone cord to the panel LINE jack and

the premises phone jack.

If a customer adds phones or other phone devices to another

phone jack, full line seizure no longer exists. Inform them to

contact you if they want to add a phone or other device so that

you can rewire for full line seizure by adding an RJ31X.