SIA system requirements are the same as those described for a

UL-listed basic system, plus if multiple annunciations are required,

use hardwired siren 13-046.

1RWH

For UL 1635 installations, entry delay plus dialer abort delay

must not exceed 60 seconds.
Table 8 below describes programming requirements to meet

ANSI-SIA CP-01.

7DEOH6,$VHWWLQJUHTXLUHPHQWV
)XQFWLRQ 'HIDXOW

VHWWLQJ

5HTXLUHG

VHWWLQJ

Entry delay

30 seconds

30 to 240 seconds

Exit delay

60 seconds

45 to 240 seconds

Dialer delay

30 seconds

15 to 45 seconds

Auto arm

On

On

Unvacated premises

On

On

Call waiting

Off

On if reporting to

central station and

customer has call

waiting service

Exit extension

On

On

Swinger shutdown

On (one trip)

On (one trip)

Fire alarm verify

Off

On

Duress/panic code

Disabled

Disabled

Cross zone

Disabled

Disabled for zones with

high probability of false

alarms

Table 9 below describes nonprogrammable (hard-coded) system

operation, as required to meet ANSI-SIA CP-01.

7DEOH1RQSURJUDPPDEOHV\VWHPRSHUDWLRQ 
)XQFWLRQ 2SHUDWLRQ

Silent exit

All annunciators enabled

Remote arming exit time and

progress annunciation

All annunciators enabled

Abort annunciation

Enabled

Cancel report annunciation

Enabled

Recent closing

Enabled (2-minute window)

Exit error

Enabled

Restoration of power

Panel resumes operation in same

arming state and disregards alarm

signals from sensors for the first 60

seconds after power restoration

Cancel alarm

Enter code only

&HQWUDOVWDWLRQUHSRUWLQJ

The panel has been tested with the following central station

receivers using SIA and Contact ID reporting formats:

1RWH

Before beginning installation, installers must verify

compatibility with the following central station receivers.

Radionics D6600 central station receiver

Sur-Gard central station receiver with models SG-DRL2A and

SG-CPM2

CS5000 digital alarm communicator receiver

8/&DQDGDOLVWHGLQVWDOODWLRQV

This section describes the requirements for CUL (UL Canada)

listed installations.
Canadian standards CSA certified accessories:

Standard Class 2, 9 VAC, 3.34 A power transformer (model 22-

153-CN).

Residential burglary alarm system unit (ORD-C1023-1974): basic

system as described for UL 1023 listed installations plus:

Hardwired magnetic contact (13-068 or 13-071) or wireless

learn mode door/window sensor (60-670)

Siren timeout set to six minutes or more

Residential fire warning system control unit (ULC-S545-M89): basic

system as described for UL 985 listed installations plus:

Wireless smoke sensor 60-848-02-95, TX-6010-01-1 learned

into sensor group 26

Siren timeout set to six minutes or more

For 24-hour backup, the total current draw for all connected

devices is limited to 250 mA (during normal standby

conditions) using a 1.2 AH battery.

)&&FRPSOLDQFH

This equipment has been tested and found to comply with the

limits for a Class B digital device, pursuant to Part 15 of the FCC

rules. These limits are designed to provide reasonable protection

against harmful interference when the equipment is operated in a

residential environment. This equipment generates, uses, and can

radiate radio frequency energy and, if not installed and used in

accordance with the instruction manual, may cause harmful

interference to radio communications.
Changes or modifications not expressly approved by the party

responsible for compliance could void the user’s authority to

operate the equipment.
FCC Part 15 registration number: B4Z-910C-SIMON

IC: 1175C-910CSIMO
Part 68. This equipment complies with Part 68 of the FCC rules

and the requirements adopted by ACTA.
FCC registration number: US: B4ZAK02B55910
Canada: 1175C-910CSIXT

Ranger Equivalence 0.2B

Load Number 0.2

P/N 466-2398 • REV B • ISS 09JAN13

7 / 8

Advertising