1RWH

Refer to specific sensor installation instructions for complete

operation and testing details.

&HQWUDOVWDWLRQFRPPXQLFDWLRQ

After performing sensor tests, check that the system is reporting

alarms successfully to the central station.

7RWHVWFRPPXQLFDWLRQZLWKWKHFHQWUDOVWDWLRQ

1. Call the central station and tell the operator that you will be

testing the system.

2. Arm the system.
3. Test each of the wireless panic buttons and trip at least one

sensor of each type (fire, intrusion, etc.) to verify that the

appropriate alarms are working correctly.
There is a 30 second delay.

4. When you finish testing the system, call the central station to

verify that the alarms were received.

6SHFLILFDWLRQV


Power

9 VAC, 60 Hz, 25 VA transformer minimum
Rechargeable battery: 6.0 VDC, 1.2 Ah lead-acid.

The battery will last 24 hours with no AC and

specified standby load of 250 mA. Maximum

battery charging current is 45 mA. With loss of

AC, panel will continue to operate normally to a

minimum of 5.1 VDC.

Radio frequency

319.5 MHz

Storage temperature -29 to 140ºF (-34 to 60ºC)
Operating

temperature

32 to 120ºF (0 to 49ºC)

Maximum humidity

85% relative humidity, noncondensing

Auxiliary power

Unregulated 5.3 to 12.3 VDC, with a maximum of

250 mA

5HJXODWRU\LQIRUPDWLRQ

8/OLVWHGLQVWDOODWLRQV

Some installation may require configurations dictated by

city/state codes, insurance, or Underwriter’s Laboratories (UL). This

section describes the various component and configuration

listings.
Basic system:

Control panel: Backup battery 6 V 1.2 Ah (34-025) (Portalac

model # PE6V1.2)

Standard class 2, 9 VAC, 3.34 A power transformer (part 22-

153). Alternate transformer for US installations: MG

Electronics model MGT925, 9 VAC, 25 VA, (part 22-155)

Hardwired siren (13-374)

Household burglary alarm system unit (UL 1023), basic system

plus the following:

Hardwired magnetic contact (13-068 or 13-071) or wireless

learn mode door/window sensor (60-670)

Panel piezo beeps set to on

Entry delay set to 45 seconds or less

Exit delay set to 60 seconds or less

RF time-out set to 24 hours

Control panel alarms turned on

Auto arm set to on

Siren timeout set to 5 minutes or more

Trouble beeps set to on

RF jam detect set to on

Hardwired siren supervision set to on

Exit extension set to off

Quick exit set to off

Household fire warning system (UL 985), basic system plus the

following:

Wireless smoke sensor 60-848-02-95, TX-6010-01-1 learned

into sensor group 26.

Panel piezo beeps turned on

Control panel alarms set to on

Siren timeout set to 4 minutes or more

Trouble beeps set to on

RF jam detect set to on

Hardwired siren supervision set to on

Smoke supervision set to on

UL 1023 and 985 24-hour backup:

For 24-hour backup, the total current draw for all connected

devices is limited to 240 mA (during normal standby

conditions) using a 1.2 AH battery.

UL 1635 digital alarm communicator system (same as UL 1023

and 985) plus the following settings are in addition to UL 1023 and

985 and are required only if the system is set up for central station

reporting:

Phone mod 1 set to 0 or 1

Automatic phone test set to 001

RF timeout set to 4 hours

AC power failure report set to on

CPU low battery report set to on

Fail to communicate set to on

Entry delay plus the dialer delay must not exceed 60 seconds