Juniper Systems Classic GG User Manual

Classic graingage quick reference sheet

Advertising
background image

FRS Main Menu
1. Collect
2. Maps
3. Setup
4. Diagnostics

Collect
1. Spatial
2. Form
3. List
4. Navigation
5. Map Traits
6. Map Identifiers

Maps
1. Add
2. Edit
3. Delete
4. View

Setup
1. System
2. Traits

Management

3. Database Tools
4. Hardware Setup
Diagnostics
1. Load Cells
2. Moisture
3. Level Detect

Sensor

4. Actuators
5. Version

Information

6. Print Calibrations

System
1. Manage Devices
2. Define Standard Units
3. Define Backup Location
4. Label Printer
5. Preferences
6. About

Traits Management
1. Master Traits List
2. Trait Template

Database Tools
1. Export data to CSV
2. Import data from CSV

Hardware Setup
1. Weight Calibration

a. Edit Weight Calibration
b. Slope and Motion

2. Moisture Sensor

a. Moisture Curve

3. Chamber Volume
4. Level Sensor
5. Timers
6. Actuators
7. Setup File
8. GPS Setup

Harvest Setup
1. Select desired Activity Harvest Plot or

Harvest Strip.

2. Select desired Field Map.
3. Select desired harvest Trait Template.
4. Select Collect.
5. Select desired Moisture Curve.
6. Select Form or Nav.
7. Select Navigation Type – Serpentine, Sequential, Circular, or Random.
8. Select the Left Range and Left Row (starting plot).

401

402

403

404

401

402

403

404

401

402

403

404

301

302

303

304

301

302

303

304

301

302

303

304

201

202

203

204

201

202

203

204

201

202

203

204

101

102

103

104

101

102

103

104

101

102

103

104

Serpentine

Sequential

Circular

Classic GrainGage Calibrating Guide
Load Cells—Calibration
1. Select Setup>System>Define Standards Units. Select English or Metric and number of decimal places.
2. Select Setup>Hardware Setup>Classic GrainGage Setup>Edit Weight Calibration

Slope and Motion Sensor needs to be turned OFF during calibration.

3. Record Weight Calibration Coefficient value.
4. In diagnostics from the main screen, select Load Cell and Tare weight.
5. Place known weight on weigh pan and verify weight reading being displayed.
6. Adjust the weight calibration using the following equation:

New Weight Cal Coefficient =Actual Weight / Measured Weight * Current Coefficient

7. Replace the current Weight Calibration Coefficient with the calculated value. Press Save (F4).

Classic GrainGage

Quick Reference

Sheet

9. Select the primary and secondary Direction of Travel.
10. Select Save.
11. Select Form.
12. Start harvesting.

Advertising