Juniper Systems JS600 User Manual
Page 39

Operating System Page 3-23
Action
Keyboard Entry
Jump back to previous register .............................. <Í>
Jump back ten registers ........................................... <SHF> <Í>
Jump back 19 registers ............................................. <SHF> <SHF> <Í>
Jump back 28 registers ............................................. <SHF> <SHF> <SHF> <Í>
Execute line ............................................................... <Ð>
Input a value, then execute line ............................. <Ð> <VALUE> <Enter>
Instructions for using Mode 6-1 follow.
Keyboard Entry
Next Message Shown
Action
<ON>
MODE?
Enter a 6 for TEST Mode.
6
TEST 1,2,3,4
Enter a 1 for submode PGM.
PGM, ANA, DIG, MEM
1
TEST PROGRAM
Enter the filename to be tested or select
FILE:
the name using the right or left arrow key.
Filename
1 OPN DATPGM
The top line shows the program line number
<Enter>
REG A __.00000000
(1), mnemonic (OPN), and parameter
(DATPGM). The bottom line shows the
register letter (A) and contents prior to
executing the instruction (.00000000).
At this point, you can view the other registers
using the right arrow key or press the down
arrow key to execute line 1 and move on to
line 2. If an instruction requires input, key it
in and press <Enter>. Continue to execute
your program until you have viewed each
line.
<Down Arrow>
to execute line or
<Right Arrow> to
view registers