Using the Test Button

The test button is located on the front right hand side of the
AXIS 1610 and is used for resetting the AXIS 1610 parameters

to the factory default settings.

Factory Default

Settings

Follow the instructions below to reset the AXIS 1610 to the

factory default settings:

1. Remove the external power supply to switch off the AXIS 1610.

2. Press and hold down the test button, while you plug the external

power supply back in. Continue to hold down the test button,
until the network indicator begins to flash at one second
intervals. This should take at least 5 seconds.

3. Release the test button and wait until the network indicator

flashes at least five times.

4. Press and hold the test button again until the network indicator

remains constantly lit.

5. Restart the AXIS 1610 by disconnecting and reconnecting the

external power supply.

The AXIS 1610 is now reset to factory default settings.

Note:

❏ All parameters except the IP Address (IP_ADDR.) and the DHCP

Enable/Disable (DHCP_ENB) parameters are reset. If you want to
change these parameters, please use any of the tools presented
in Configuration Overview, on page 32.