Service Manual NeoTherm 80 - NeoTherm 285

9. Now you can remove the air/gas channel

and blower assembly from the machine.

Remove the five #25 Torx-head screws

around the air/gas channel. See Fig. B11-

7. (These are the outer screws on the front

of the assembly. The inner screws attach

the cover on the air/gas channel - do not

remove these.)

10. Support the assembly as you remove the

last screws, so it does not fall. Figure B11-

8 shows how the assembly looks once it

has been removed.

Remove

these

screws

Fig. B11-7 - Removing the air/gas channel and attached blower

Gas valve

Venturi

Fig. B11-8 - Gas valve still attached to blower and Venturi

Removing and Replacing the Gas Valve (continued)

B11

cont.

8. The gas inlet pipe runs to the underside of the gas

valve. It is attached by four 3mm Allen-head screws,

and these are difficult to reach. Figure B11-6 shows

the screws as seen from below the gas valve.

Use a 3mm Allen wrench to undo these screws. It

will be hard to reach one of the screws. The best tool

for this job is a traditional “L-shaped” Allen wrench,

with one long leg and one short leg. You will be able

to use the short leg to undo that one difficult screw.

Fig. B11-6 - Four mounting screws for the gas inlet

pipe, viewed from below

Screws