LAARS NeoTherm NTV (Sizes 150–285 MBTU/h) - Service Manual User Manual

Page 42

Advertising
background image

32

Service Manual NeoTherm 80 - NeoTherm 285

Tools and equipment required:
* 1/4” socket
• Small diagonal cutters or knife
• Water-pump pliers
• 11” Ty-wrap

Procedure
1. Turn off power to the system. Use the main disconnect switch

mounted above the front panel.

2. Remove the front panel from the unit.
3. You won’t be able to do this procedure unless you also remove the

panel on the right side of the unit. Remove the mounting screws,

then remove the right side panel.

4. Disconnect the two wires from the top of the trap assembly.
5. Notice the position of the Ty-wrap, then cut it.
6. Use the water-pump pliers to remove the clip holding the inlet hose

(lower end of the trap assembly). Pull the end of the hose away

from the trap assembly.

7. Once the assembly is free, flush it out with water to remove any col-

lected sediment.

8. To replace the assembly, reverse the steps we have just described.

It does not matter which way the wires are connected.

Removing and Replacing the Condensate Trap (continued)

B14

cont.

Advertising
This manual is related to the following products: