General Information Assembling Vent Pipes

584-15

Fig. 15 Termination clearances.

Flex Vent Pipes

Before joining the flex vent pipe to the unit, apply a
bead of high temperature sealant* (provided) to the 4”
pipe exiting the fireplace. Secure flex vent pipe in place
with a hose clamp (provided).
*Be sure the flex pipe overlaps at least 1” (25mm) onto
the collars of the fireplace and termination. If the ter-
mination has an internal bead, be sure to overlap and
secure 1” (25 mm) past the bead.

FP1471

flex vent

Apply High Temperature

Sealant

Hose Clamp

FP1471

Fig. 16 Apply high temperature sealant to 4” and 7” pipes.

Canadian Installations
The venting system must be installed in accordance
with the current CSA-B149.1 installation code.
USA Installations
The venting system must conform to local codes and/or
the current National Fuel Code ANSI Z223.1/NFPA 54.
Only venting components manufactured by CFM Corpo-
ration may be used in Direct Vent systems.

* Be sure the vent is actually crushed before proceed-
ing. Apply a tug to be sure the vent will not slip off the
collars.
Repeat process with 7” flex vent pipe. The same proce-
dure must be performed on the vent side.

Outside Corner

Inside Corner

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

A =

Combustible

6"(152 mm)
Noncombustible

2"(51 mm)

B =

Combustible

6"(152 mm)

Noncombustible

2"(51 mm)

A

Balcony -

with no side wall

G =

Combustible&

Noncombustible

12"(305 mm)

G

Balcony -

with perpendicular side wall

H = 24"(610 mm)

J = 20"(508 mm)

H

J

B

Recessed Location

C = Maximum depth of 48"

(1219 mm) for recessed

location.

D = Minimum width for back wall

of a recessed location.

Combustible 38"(965 mm)

Noncombustible 24"(610 mm)

E = Clearance from corner in

recessed location.

Combustible 6"(152 mm)

Noncombustible 2"(51 mm)

C

D

C

E

V

V

Combustible &

Noncombustible

V

V

V