Dvbr series direct vent gas fireplace, Dvbr42 – Vermont Casting DVBR42 User Manual
Page 9

9
DVBR Series Direct Vent Gas Fireplace
20000584
4. Remove the four (4) screws securing flue cover to
top of unit and remove flue cover. (Fig. 11)
5. Remove the four (4) screws securing flue pipe to
back of unit. Remove flue pipe. (Fig. 11)
6. Secure flue cover to back of flue outlet. Be sure to
replace gasket. (Fig. 12)
7. Install flue pipe to top of unit with four (4) screws. Be
sure to replace gasket. (Fig. 12)
8. Set insulation in back of unit foil side down.
9. Secure outer collar adapter to unit with the round
collar on top, secure with eight (8) screws.
NOTE: Be sure not to damage any gasket material.
DVT584-603
Outer Collar Adapter
Flue Pipe
3/11/99 djt
Insulation
Remove
Screws (4)
Remove Screws
(4)
Flue
Cover
Flue
Pipe
DVT584-603
Fig. 11 Remove flue cover and flue pipe.
DVT584-604
Outer Collar Adapter
Flue Pipe
3/11/99 djt
Flue
Pipe
Foil Side
Replace
Screws
(4)
Insulation
Flue Pipe
DVT584-604
Fig. 12 Replace flue cover and flue pipe.
Replace
Screws (4)
DVT584-602
Outer Collar Adapter
Flue Pipe
3/11/99 djt
Flue Pipe
Remove
Screws (4)
Outer Collar
Adapter
Remove Screws (4)
DVT584-602
Rear View
Fig. 10 Remove screws from outer collar adapter.
DVT584-605
Outer Collar Adapter
Flue Pipe completed
3/11/99 djt
DVT584-605
Fig. 13 Completed conversion.
DVBR42
1. Remove the seven (7) screws securing the heat
shield cover plate to the fireplace. (Fig. a) Discard
the heat shield cover plate.
FP1542
DVBR42 heat shld
cover plate
1/05
Remove Screws (7)
Heat Shield
Cover Plate
FP1542
Fig. a Remove screws securing heat shield cover plate. Dis-
card cover plate.