Dvbr series direct vent gas fireplace, Fuel conversion instructions, Valve conversion - honeywell valve – Vermont Casting DVBR42 User Manual

Page 30: Valve conversion - sit valve, Burner orifice conversion

Advertising
background image

30

DVBR Series Direct Vent Gas Fireplace

20000584

4. For conver-
sion to Natural
Gas remove the
manifold mounting
bracket. Replace
the nut and screw
removed earlier.
Attach the air shut-
ter to the burner

tube and secure with screw. Tighten screw. For con-
version to LP Gas, remove the air shutter retaining
screw and remove air shutter. Remove the hex nut
and screw as shown in Figure 65. Slide the manifold
mounting bracket onto the manifold where the split
nut was removed. Slide the split nut on and install
the orifice. Tighten the orifice. (Fig. 66) Assemble the
manifold mounting bracket to the burner where the
nut and screw were removed. Tighten the nut and
screw.

5. For conversion to natural gas re-install manifold

to burner pan with 3/4” wrench and tighten until
secure.

Fuel Conversion Instructions

To convert the DVBR unit from one gas type to another
follow these instructions:
1. Remove control cover to gain access to valve.

Remove glass door. (See “Glass Frame Removal”,
Page 23, Fig. 48)

2. Remove logs if previously installed.

Valve Conversion - Honeywell Valve

3. Remove cap from HI/LO knob. This can be accom-

plished by lifting the plastic cap off the screw. (Fig.
59)

4. Remove the screw from center of HI/LO knob with

small screwdriver turning counterclockwise. (Fig. 59)

CO101

Gas Conversion

Manifold

2/12/99 djt

Manifold
Assembly

Orifice

Log Support

Pilot

Fig. 61 Remove manifold assembly.

CO101

Burner Pan

5. Insert conversion screw (supplied in conversion kit)

in center of HI/LO knob. Blue for natural gas, red for
LP.

6. Tighten screw, replace cap.
Valve conversion is complete.

Valve Conversion - SIT Valve

1. Using the TORX T20 bit, remove and discard the

three (3) pressure regulator mounting screws (A),
pressure regulator tower (B) and the spring and
diaphragm assembly (C(). (Fig. 60) NOTE: If the
conversion is for the 822 electronic valve, cut the
metal tab off the regulator as shown in Figure 60.

2. Insure the rubber gasket (D) is properly positioned

and install the new HI/LO pressure regulator assem-
bly to the valve using the new screws (E) supplied
with the kit. Tighten the screws securely. (Ref. torque
= 25 in/lb) (Fig. 60)

3. Install the enclosed conversion label (F) to the valve

body where it can easily be seen. (Fig. 60)

Valve conversion is complete.

Burner Orifice Conversion

1. Unscrew manifold assembly from burner using 3/4”

wrench. (Fig. 61)

2. Remove burner orifice from manifold assembly using

1/2” wrench. (Fig. 62)

3. Remove air shutter from burner pan by removing

shutter retaining screw then air shutter. (Fig. 63)

CO100

Gas conversion

HI-LO knob

3/15/99 djt

LO

HI

LO

HI

Hi-Lo Knob

Cap

Lift Open

Fig. 59 Remove center screw from Hi-Lo knob.

Remove

Center Screw

CO100

CO102

Gas Conversion

2/15/99 djt

CO102

Burner

Orifice

Fig. 62 Remove burner orifice,
replace with conversion orifice.

FC107

SIT820

valve conversion

10/03

A

B

C

OFF

PIL

OT

O

D

E

F

FC108

SIT

regulator

conversion

10/03

OFF

PIL

OT

O

Fig. 60 Remove mounting screws, pressure regulator tower

and spring and diaphragm assembly. Replace regulator.

FC107/108

Cut here

for 822

Valve

Advertising