View machine id number, View cup ring cycles related to posivend, View home switch usage related to posivend – CMS Products 674 User Manual

Page 72: Posivend hotcup operators’ guide

Advertising
background image

PosiVend

HotCup Operators’ Guide

6740001

66

November, 2007

VIEW MACHINE ID NUMBER

a. Press

, then press

or

until the display shows

I.D. XXXXXX

. The

X

’s

represent the 6-digit machine ID number.

b. You can edit the machine ID number if the supervisor access code has been previously

entered (See “Gain Access to the Supervisor Mode” on page 38).

c. Continue.

VIEW CUP RING CYCLES RELATED TO POSIVEND™
(Not shown if zero)

a. Press

, then press

until the display shows

PV.TOT xx

.

XX

represents the

number of vends during which more than one ring cycle was required to successfully
dispense a cup.

b. Press

to clear the count.

c. Continue.

VIEW TIMES NO CUP WAS DETECTED AFTER A CUP RING CYCLED
(Not shown if zero)

a. Press

, then press

until the display shows

PV.FL1 xx

.

XX

represents the

number of times a cup was not detected after ring 1 cycled. Check the cup ring adjustment
(see the Operator’s Guide), or the cup stack for damage if the count is excessive.

b. Press

to clear the count.

c. Press

until the display shows

PV.FL2 xx

.

XX

represents the number of times a cup

was not detected after ring 2 cycled. Check the cup ring adjustment (see the Operator’s
Guide
), or the cup stack for damage if the count is excessive.

d. Continue.

VIEW HOME SWITCH USAGE RELATED TO POSIVEND™
(Not shown if zero)

a. Press

, then press

until the display shows

WO.PV xx

.

XX

represents the

number of times home switches were used due to

opt

n

posi.v

selected but not working.

b. Continue.

Advertising