HotCup Operators’ Guide

PosiVend

November, 2007

67

6740001

VIEW POSIVEND™ LAST RECORDED CALIBRATION VALUE

a. Press

PosiVend™ until the display shows

cal.lst xxx

.

XXX

can be any number from

0 to 255, and represents the most recent value read from the sensor. The lower the number
the greater the sensor blockage. A number of 255 means that there is a fatal problem with
the PosiVend™ interface board. Ensure the PosiVend™ interface PCB is properly connected
to the main controller PCB.

b. Continue.

VIEW POSIVEND™ AVERAGE CALIBRATION VALUE

a. Press

, then press until the display shows

cal.ave xxx

.

XXX

represents the average

sensor calibration value (should be between 50 and 255 for proper sensor operation - i.e. 51
through 254). Although this number could go as low as 20, the PosiVend™ system will be
inoperative in this condition.

b. Continue.