• All gas piping must be installed in compliance with

local codes and utility regulations. In the absence

of local codes the gas line installation must comply

with the latest edition of the National Fuel gas Code

ANSI Z223.1 or CAN/CgA b149 Installation Codes.

• Some local codes require the installation of a

manual main shut-off valve and ground joint union

external to the furnace (Figure 9). The shut-off

valve should be readily accessible for service and/

or emergency use. Consult the local utility or gas

supplier for additional requirements regarding

placement of the manual main gas shut-off.

The manifold pressure must be set to the

appropriate value for your installation. Refer to the

Manifold Pressure Adjustment section (page 19)

for adjustment instructions.

• gas piping must never run in or through air ducts,

chimneys, gas vents, or elevator shafts.

• Compounds used to seal joints on gas piping must

be resistant to the actions of LP propane gas.

• The main gas valve and main power disconnect to

the furnace must be properly labeled by the installer

in case emergency shutdown is required.

• An 1/8 inch NPT plugged tap must be installed in

the gas line immediately upstream of the gas supply

connection to the furnace for use when measuring

the gas supply pressure. The plug should be readily

accessible for service use.

• A drip leg should be installed in the vertical pipe

run to the unit (Figure 9).

This unit only has right side gas entry. When connecting
the gas, provide clearance between the gas supply line
and the entry hole in the unit’s casing to avoid unwanted
noise and/or damage to the unit. A typical gas service
hookup is shown in Figure 9.

Table 13 (page 28) lists gas pipe capacities for standard
pipe sizes as a function of length in typical applications
based on nominal pressure drop in the line.

Ground

Joint

Union

Dripleg

Shut-Off Valve

with 1/8 NPT

plugged tap

Burner
Assembly

Manifold

Some utilities

require Shut-Off

Valve to be

4 to 5 feet

above floor

Automatic Gas Valve

(with manual shut-off)

Figure 9. Typical gas Hookup - Right Side Entry

gAS SUPPLY & PIPINg

WARNING:

FIRE OR EXPLOSION HAZARD

• Failure to follow safety warnings exactly

could result in serious injury or property
damage.

• Installation and service must be performed

by a qualified installer, service agency or the
gas supplier.

• Do not store or use gasoline or other

flammable vapors and liquids in the vicinity
of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Leave the building immediately.
• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call

the fire department.

AVERTISSEMENT:

RISQUE D’INCENDIE OU D’ EXPLOSION

• Le non-respect des avertissements de sécurité

pourrait entraîner des blessures graves, la mort
ou des dommages matériels.

• L’installation et l’entretien doivent être effectués

par un installateur qualifié, un organisme de
service ou le fournisseur de gazstaller, service
agency or the gas supplier.

• Ne pas entreposer ni utiliser de l’essence ni

d’autres vapeurs ou liquides inflammables dans le
voisinage de cet appareil, ni de tout autre appareil.

QUE FAIRE S’IL Y A UNE ODEUR DE GAZ

• Ne pas tenter d’allumer aucun appareil.
• Ne toucher à aucun interrupteur électrique;

n’utiliser aucun téléphone dans le bâtiment.

• Évacuer l’immeuble immédiatement.
• Appeler immédiatement le fournisseur de gaz en

employant le téléphone d’un voisin. Respecter à
la lettre les instructions du fournisseur de gaz.

• Si personne ne répond, appeler le service des

incendies.

Advertising
This manual is related to the following products: