COMPONENT FUNCTIONS

Comfort Alert™ Diagnostics -The Comfort Alert
diagnostics module troubleshoots heat pump and air
conditioning system failures and accurately detects the
cause of electrical and system related failures without
any sensors. A flashing LED indicator communicates the
ALERT code to quickly direct the technician to the root
cause of a problem.

Flame Roll-Out Control - The flame roll-out control acts to
verify that the burner flame is being drawn into the heat
exchanger tubes. If the burner flame is not being drawn
into the heat exchanger tubes, the roll-out control will
open within several seconds and the integrated control
diagnostic light will flash one time. If the limit opens, the
integrated control diagnostic will flash one time. The
circulating air blower will continue to operate while the
flame roll-out control is open.

Flame Sensor - The flame sensor acts to prove that flame
has carried over from the ignitor to the right-most burner. If
no flame is sensed, the unit will be shut down automatically.

Dual Pressure Switch - The dual pressure switch verifies
that the inducer motor is drawing the combustion gases
through the heat exchanger tubes and venting the
gases through the vent system for both high and low fire
conditions.

Gas Valve - The gas valve controls the flow of gas to the
burners in both low and high fire. When the gas valve is
energized it automatically opens and regulates the gas
pressure in the manifold. See Figure 10 below.

REPLACEMENT PARTS

Replacement parts are available through all Nordyne
distributors. Please have the complete model and serial
number of the unit when ordering replacement parts.

Electrical:

• Capacitors

• Pressure Switches

• Compressors

• Relays

• Contactors

• Reversing Valve Solenoid

• Defrost Control Board

• Temperature Limit Switches

• Gas Valves

• Thermostats

• Ignition Controls

• Time Delay Relays

• Ignitors/Flame Sensors • Transformers

Motors:

• Blower Motor
• Fan Motor
• Inducer Blower Motor

Components:

Blower Assembly

• Fan Grille

Burner Manifold

• Filter/Driers

Burners/Orifices

• Gaskets

Cabinet Panels

• Heat Exchanger

Expansion Valves

• Reversing Valve

IN

ON

OFF

Inlet

Pressure

Tap

Inlet

Pressure

Tap

Manifold

pressure

Tap

Manifold

pressure

Tap

2-STAGE GAS VALVES

Model VR8205Q2381

Model VR9205Q1028

ON / OFF

Knob

ON / OFF

Switch

HI Input

Adjusting Screw

Lo Input
Adjusting Screw

HI Input

Adjusting

Screw

Lo Input

Adjusting

Screw

Figure 10. HI & LO Input Adjusting Screws

Over-Temperature Limit Control - The over-temperature
limit control prevents the air temperature leaving the unit
from exceeding the maximum outlet air temperature. If the
limit opens, the integrated control diagnostic will flash one
time. The circulating air blower will continue to operate
while the over-temperature limit control is open.