Wiring dia gram – Reznor PDF2SF Unit Installation Manual User Manual

Page 33

Advertising
background image

33

Figure 16. Two Stage Cool, Two Stage Heat (Heat Pump)

Two-Stage gas Heating (3 & 4 Ton)

FIELD

WIRING

LEGEND:

LO

W

VO

LT

AG

E

HIGH

VO

LT

AG

E

1.

Couper le courant

av

ant de faire letretien.

2.

Emplo

yez uniquement des conducteur

s en cuivre

.

3.

Ne con

vient pas aux installations de plus de 150

V a la terre

.

208/230

V

olt

.

z

H

0

6 /

e

s

a

h

P

el

g

ni

S

m

et

s

y

S

d

e

g

a

k

c

a

P

g

nil

o

o

C

d

n

a

g

ni

t

a

e

H l

e

u

F l

a

u

D

NO

TES:

1.

Disconnect po

wer bef

ore servicing.

2.

For supp

ly

connections use copper conducto

rs

on

ly

.

3.

Not suitable on systems that

ex

ceed 150V to gr

ound.

4.

If an

y of the original wire as supplied with the furnace m

ust be replaced

,

it m

ust

be replaced with wiring material ha

ving a temperature rating of at least 105°C.

5.

For suppl

y wire ampacities and

ov

er

current pr

otection,

see unit rating plat

e.

6.

Ensure that wires fr

om the blo

wer remain connected to the boa

rd

thermostat terminals after

making the field thermostat connections.

7.

A heat pump thermostat with f

ossil fuel bac

k-up heat capability is REQUIRED

fo

r this system.

WIRING DIA

GRAM

SYSTEM ST

A

TUS - IGNITION

Po

wer On (Nor

mal Operation)

High Limit Circuit Open

Pressure Switch Open with Inducer On

Pressure Switch Closed with Inducer Off

F

ailed Ignition (5 attemps) - Control in 1 Hour Loc

k

out

208-230

V

olt P

olar

ity Issue

Excess High limit tr

ips (5) within one call f

or heat

Excess pressure s

witch cycles (5) within one call f

or heat

Excess flame dropouts (5) within one call f

or heat

Not Used

Flame present with gas

va

lv

e Off

LED ST

A

TUS (RED)

ON

1 Flash

2 Flashes

3 Flashes

4 Flashes

5 Flashes

6 Flashes

7 Flashes

8 Flashes

9 Flashes

10 Flashes

SYSTEM ST

A

TUS - 2nd ST

A

GE HE

AT

DEMAND

No demand f

or 2nd stage heat

2nd stage heat demand (Nor

mal operation)

2nd stage heat demand, high pressure

sw

itch not closed

LED ST

A

TUS (GREEN)

OFF

ON

Flashing

SYSTEM ST

A

TUS - CFM

NO

T USED

LED ST

A

TUS (YELLO

W)

OFF

SYSTEM ST

A

TUS - HI/LO DEHUMIDIFY (Cooling Mode on

ly

)

F

actor

y jumper wire

“R

to

“DEHUM”

in place or

“Close on F

all”

humidistat (Lo

w humidity) - Closed

Humidistat open (High Humidity) Lo

w Speed Bl

ow

er call

LED ST

A

TUS (GREEN)

ON

OFF

DEFR

OST BO

ARD OPERA

TION:

-- Heat Pump operates in heating mode until the combination of outdoor ambient

and outdoor coil temperatures initiate a defrost cycle. The outdoor coil

temperature must be at or below 32˚F before the defrost cycle begins.

-- There must be a minimum of 20 minutes between defrost cycle

s.

After this

time, temperature conditions must call for defrost continuously for 4 1/2

minutes before a defrost cycle is initiated.

-- The defrost cycle ends when either the outdoor coil temperature sensor reaches

the defrost terminate set point, or 13 minutes, 39 seconds of compressor run time

has elasped with the control in the defrost mode. (See installation instructions for

available terminate temperatures and their specific jumper location)

7113340

(Replaces 7111860)

2/13

GAS

VA

LV

E

624787

GAS

VA

LV

E

624652

HI

LO

GAS

VA

LV

E

C

BR

OW

N

YELLO

W

YELLO

W

BR

OW

N

TEST

LR

CY

O

W2

IN

W2

OUT

COND

FA

N

AMBIENT

AMBG

COILG

COIL

DEMAND

DEFR

OST CONT

RO

L

BO

ARD

M

PRESS

SW

REV

VA

LV

E

2

1

3

6

5

4

7

8

9

12

11

10

W1

W2

C

R

G

Y

Y2

0

DEHUM

P2

1

5

(CFM)

YEL

GREEN

HI/LO

DEHUMIDIFY

1

2

3

1

2

3

INDUCER

MO

TO

R

FLAME R

OLL-OUT

SWITCH

HIGH

TEMP LIMIT

SWITCH

FLAME SENSOR

LPS

DU

AL CA

PA

CIT

OR

TERM.

STRIP

REV

. VA

LV

E

SOLENOID

5

432

1

5

432

1

VA

RIABLE

SPEED

BLO

WER

MO

TO

R

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

R

S

C

C

HF

TO

208/230

VA

C

PO

WER SUPPL

Y

IGNIT

OR

CONT

AC

TO

R

COMPRESSOR

L1

L2

T1

T2

COIL

SENSOR

AMBIENT

SENSOR

G

C

L

W1

R

Y2

E

O

Y1

W2

TRANSFORMER

240V

208V

24V

COM

BR

OW

N

BR

OW

N

BLA

CK

BLA

CK

CCH

IF

EQUIPPED

HPS

YELLO

W

YELLO

W

IGNITION / BLO

WER

CONTR

OL BO

ARD

HUM

LINE

XMFR

CO

NT

EA

C

COOL

PARK1

PA

RK2

HI-HEA

T

LO

-HEA

T

P6

16-

PIN

BLUE

BL

AC

K

YELLO

W

WHITE

BR

OW

N

YELLO

W

YELLO

W

5A FUSE

BLUE

BLUE

(HIGH HE

AT

DEMAND)

GREEN

(S

TA

TUS)

RED

NEUTRALS

AU

TO

HEA

T ST

AG

E

10 5 NONE

COOL

A B C D

HEA

T

A B C D

ADJUST

NORM

(+)

(-)

TEST

LO

W

PRESSURE

SWITCH

HIGH

PRESSURE

SWITCH

HI

LO

GAS

VA

LV

E

C

2

1

3

OUTDOOR

MO

TO

R

L

N

G

1

2

3

YE/GN

RED

YELLO

W

BLA

CK

BLUE

BLUE

BL

AC

K

RED

BR

OW

N

BR

OW

N

BLACK

RED

GREEN

BL

AC

K

VIOLET

ORANGE

WHITE

BLA

CK

BLACK

BLA

CK

BLA

CK

GREEN

YELLO

W

YELLOW

YELL

OW

YELL

OW

BROW

N

BR

OW

N

GREEN

YELL

OW

ORANGE

BLUE

RED

BLA

CK

WHITE

WHITE

BROW

N

YELLOW

ORANGE

RED

BLACK

BLACK

WHITE

BR

OW

N

GREEN

YELLO

W

ORANGE

BLUE

RED

BL

AC

K

RED

RED

WHITE

RED

WHITE

WHITE

WHITE

BL

AC

K

YELLOW

YELLO

W

WHITE

RED

BLUE