Introduction – Slant/Fin Gas Hot Water User Manual

Page 2

Advertising
background image

2

* Specify gas by name, "Natural" or "Propane".

† Net ratings are based on piping and pick-up allowance of 1.15. Slant/Fin should

be consulted before selecting a boiler for installation having unusual piping and/or

pick-up requirements. Ratings must be reduced by 4% at 2,000 ft. elevation and

an additional 4% for every additional 1,000 ft. elevation over 2,000 ft.

‡ Net ratings in square feet based on emission rate of 150 Btuh/sq. ft.

§ Refer to figures 1 and 8. Headers shown are optional.

‡‡All factory supplied headers use 3" system connections.

Modules in excess of 10 should be piped in parallel in two or more batteries.

Note: For higher capacities, specify correct combination of standard Caravan

modules shown.

FOR LARGER SIZES, USE MULTIPLES OF THE ABOVE.

Table 1: Gas Caravan ratings and dimension/hot water model—GGT Series (100 psi maximum working pressure)

GGT-600E

2

GG-300ES

600

486

2814

422

14.5

81.10

18.4

1080

26

11

16

59

5

8

8

12

1

32

21

13

16

5

5

16

4'11"

2"

GGHT-700E

2

GG-350HES

700

570

3306

496

17.0

81.40

20.6

1230

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

5'2"

2"

GGHT-750E

2

GG-375HES

750

606

3506

526

18.1

80.90

20.6

1230

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

5'2"

2"

GGHT-800E

2

GG-399HES

798

644

3734

560

19.2

80.60

20.6

1230

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

5'2"

2"

GGT-900E

3

GG-300ES

900

729

4221

633

21.8

81.10

27.6

1590

26

11

16

59

5

8

8

12

1

32

21

13

16

5

5

16

7'7"

2"

GGHT-1050E

3

GG-350HES

1050

855

4959

744

25.5

81.40

30.9

1830

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

7'10"

2"

GGHT-1125E

3

GG-375HES

1125

909

5259

789

27.2

80.90

30.9

1830

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

7'10"

2"

GGHT-1200E

3

GG-399HES

1197

966

5601

840

28.9

80.60

30.9

1830

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

7'10"

3"

GGT-1200E

4

GG-300ES

1200

972

5628

844

29.0

81.10

36.8

2140

26

11

16

59

5

8

8

12

1

32

21

13

16

5

5

16

10'3"

3"

GGHT-1400E

4

GG-350HES

1400 1140

6612

992

34.1

81.40

41.2

2440

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

10'6"

3"

GGHT-1500E

4

GG-375HES

1500 1212

7012

1052

36.2

80.90

41.2

2440

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

10'6"

3"

GGT-1500E

5

GG-300ES

1500 1215

7035

1055

36.3

81.10

46.0

2675

26

11

16

59

5

8

8

12

1

32

21

13

16

5

5

16

12'11"

3"

GGHT-1600E

4

GG-399HES

1596 1288

7468

1120

38.5

80.60

41.2

2440

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

10'6"

3"

GGHT-1750E

5

GG-350HES

1750 1425

8265

1240

42.6

81.40

51.5

3050

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

13'2"

3"

GGHT-1875E

5

GG-375HES

1875 1515

8765

1315

45.3

80.90

51.5

3050

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

13'2"

3"

GGHT-2000E

5

GG-399HES

1995 1610

9333

1400

48.1

80.60

51.5

3050

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

13'2"

3"

GGHT-2100E

6

GG-350HES

2100 1710

9918

1488

51.1

81.40

61.8

3660

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

15'10"

3"

GGHT-2250E

6

GG-375HES

2250 1818

10518

1578

54.3

80.90

61.8

3660

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

15'10"

3"

GGHT-2400E

6

GG-399HES

2394 1932

11202

1680

57.7

80.60

61.8

3660

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

15'10"

3"

GGHT-2450E

7

GG-350HES

2450 1995

11571

1736

59.6

81.40

72.1

4270

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

18'6"

3"

GGHT-2625E

7

GG-375HES

2625 2121

12271

1841

63.4

80.90

72.1

4270

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

18'6"

3"

GGHT-2800E

7

GG-399HES

2793 2254

13069

1960

67.3

80.60

72.1

4270

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

18'6"

3"

GGHT-2800AE

8

GG-350HES

2800 2280

13224

1984

68.1

81.40

82.4

4880

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

21'2"

3"

GGHT-3000E

8

GG-375HES

3000 2424

14024

2104

72.4

80.90

82.4

4880

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

21'2"

3"

GGHT-3150E

9

GG-350HES

3150 2565

14877

2232

76.6

81.40

82.4

5490

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

23'10"

3"

GGHT-3200E

8

GG-399HES

3192 2576

14936

2240

77.0

80.60

82.4

4880

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

21'2"

3"

GGHT-3375E

9

GG-375HES

3375 2727

15777

2367

81.5

80.90

92.7

5490

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

23'10"

3"

GGHT-3500E

10

GG-350HES

3500 2850

16530

2480

85.1

81.40

92.7

6100

30

1

16

67

1

8

9

13

23

32

25

3

16

1

15

16

26'6"

3"

GGHT-3600E

9

GG-399HES

3591 2898

16800

2520

86.6

80.60

92.7

5490

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

23'10"

3"

GGHT-3750E

10

GG-375HES

3750 3030

17530

2630

90.5

80.90

103.0

6100

30

1

16

59

5

8

10

13

23

32

25

3

16

1

15

16

26'6"

3"

GGHT-4000E

10

GG-399HES

3990 3220

18670

2800

96.2

80.60

103.0

6100

30

1

16

66

5

8

10

13

23

32

25

3

16

1

15

16

26'6"

3"

No.of

Htg.

Mod.

Module

Model

Number

CSA

Input

Gross

Output

EDR

Water‡

(Sq.Ft.)

AHRI

Net

Output†

Boiler

Horse-

power

Water

Content

(gal.)

Thermal

EFF.

%

Ship

Wt.

Jkt.

Width

Draft

Hood

Ht.

Flue

Collar

Draft

Hood

Ht.

Header

to

Header

Space

Btwn.

Mods.

Length

with

Header

Min.

Header

Size‡‡

Consists of

Ratings

Model No.

INTRODUCTION

This Caravan application manual is intended to simplify the selection
and application of Slant/Fin modular systems for a variety of space
heating and domestic hot water requirements. It applies to

gas-fired, hot water applications only. Where intermittent pilot, vent
damper or any additional information is required, contact your local
wholesaler, Slant/Fin sales representative, or the Slant/Fin factory.

Due to design flexibility of a Caravan modular boiler system, BTU
input capacities are unlimited.

A. Boiler room design, size and flexibility - since Caravan

modules have the burner and controls mounted to the front, they
can be installed with minimum clearances as per codes, thus
saving a significant amount of floor space.

B. Faster, easier installation - modules are completely factory

assembled, including individual jackets to save on-site labor.

Optional easy to install return and supply headers with flexible
quick connect fittings are available for hot water systems.

C. Safety - each module contains an individual high limit control

and a dual combination gas valve. ASME relief valve is provided
separately for mounting directly on each module.

D. Fast domestic hot water recovery - Caravan offers an external

heat exchanger of the positive circulating type.

Advertising