Slant fin corp – Slant/Fin CHS-399 User Manual

Page 24

Advertising
background image

Slant Fin Corp.

│ Installation and Operation Instructions

CHS Series

24

Figure 4-7 Venting Below Grade

For installations that exit the wall below grade:

1. Excavate site to a point below where the pipes

are to exit as shown.

2. Ensure the wall is fully sealed where the pipes

penetrate.

3. The Vent/Air-inlet piping MUST be secured to

the side of the building above grade, as shown,
to provide rigidity.

4. Optional mounting bracket PN. 82075 for

securing the exhaust pipes (only applicable for
3” PVC/CPVC venting).

5. Ensure that the Vent/Air-inlet clearances are

maintained, see Section 5.0 for details.

Figure 4-8 Outdoor Venting

Vent piping outside the building is permitted under
the following conditions:

1. The maximum length outside the building is 20

feet [6.1 m]. Note that outdoor length must be
included in the overall vent length calculation.

2. All normal termination clearances are maintained.
3. The pipe is supported every 24” [610 mm].
4. The exhaust and air-inlet are sloped back to the

boiler ½” elevation for every linear foot [13 mm
for every linear 305 mm].


Figure 4-9 Existing Chimney Chase Way

It is permissible to use an existing chimney as a chase
way to run the Vent/Air-inlet piping as long as:

1. The chimney is not being used by any other

boiler.

2. Flue gases don’t enter the vacant chimney.
3. Only CHS certified venting materials are used,

see Section 4.0.

4. Vent lengths are within the maximums specified.
5. The top of the chimney is capped and the

Vent/Air-inlet pipes are flashed to prevent
leakage into the vacant chimney.

Air-Inlet

Existing
Chimney
(used as a
chase way)

Chimney
Cap

Exhaust Vent

Exhaust Vent Min.
18” [457 mm]
above air-inlet
Air-Inlet
Min. 12” [305 mm]
above roof and
snow level

Supports every
24” [610 mm]

12” [305 mm] plus snow

allowance above grade

Air-Inlet

Maximum of 20 ft
[6.1 m] is permitted
for piping outside a
building.

Exhaust
Vent

Gas Vent Directly Below

Keep Free of Obstructions

Exhaust

Air-inlet

Wall Brackets

Advertising