Slant fin corp – Slant/Fin CHS-399 User Manual

Page 69

Advertising
background image

CHS Series

Installation and Operation Instructions │

Slant Fin Corp.

69

Table 15-1 Troubleshooting Chart

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Blown fuse

Check Fuse

"

A

"

using the procedure described

above. Fuse

"

A

"

protects the blower as well as the

ignition spark generator and appliance pump.

Faulty blower

Measure voltage across pins 1 & 2 (black and
white wires) of 3-position connector on wiring
harness. If 120VAC detected, replace power
connector and remove 5-position signal connector.
Blower should rotate at high speed. If blower does
not rotate, replace blower.

Table 15-2 Thermistor Resistance vs. Temperature

Temp °F (°C)

Resistance Ohms (Ω)

Temp °F (°C)

Resistance Ohms (Ω)

-22 (-30)

176,133

122 (50)

3,603

-4 (-20)

96,761

131 (55)

2,986

14 (-10)

55,218

140 (60)

2,488

32 (0)

32,650

149 (65)

2,083

41 (5)

25,390

158 (70)

1,752

50 (10)

19,900

167 (75)

1,481

59 (15)

15,710

176 (80)

1,258

68 (20)

12,490

185 (85)

1,072

77 (25)

10,000

194 (90)

918

86 (30)

8,057

203 (95)

789

95 (35)

6,531

212 (100)

680

104 (40)

5,327

230 (110)

506

113 (45)

4,369

-

-


Table 15-3 Hold and Lockout Codes

Code

Description

Note

0

None

Hold / No lockout

1

Unconfigured safety data

Lockout

2

Waiting for safety data verification

Lockout

3

Internal fault: Hardware fault

Hold

4

Internal fault: Safety Relay key feedback error

Hold

5

Internal fault: Unstable power (DCDC) output

Hold

6

Internal fault: Invalid processor clock

Hold

7

Internal fault: Safety relay drive error

Hold

8

Internal fault: Zero crossing not detected

Hold

9

Internal fault: Flame bias out of range

Hold

10

Internal fault: Invalid Burner control state

Lockout

11

Internal fault: Invalid Burner control state flag

Lockout

12

Internal fault: Safety relay drive cap short

Hold

13

Internal fault: PII shorted to ILK

Hold / Lockout

14

Internal fault: HFS shorted to LCI

Hold / Lockout

15

Internal fault: Safety relay test failed due to feedback ON

Lockout

16

Internal fault: Safety relay test failed due to safety relay OFF

Lockout

17

Internal fault: Safety relay test failed due to safety relay not OFF

Lockout

18

Internal fault: Safety relay test failed due to feedback not ON

Lockout

19

Internal fault: Safety RAM write

Lockout