2.0 SPECIFICATIONS

Common Vent Manifold Configurations

The CHS 300-399 Common Venting is available in 2 configurations; each configuration is applicable to a certain
boiler combination. The manifolds can be assembled to direct Exhaust Gas and Combustion Air-Inlet piping to
the left or right.

Table 2-1 CHS 300-399 Common Venting

PART NO.

DESCRIPTION

COMMON VENTING IMAGE

818 192

Common Venting for the Exhaust Vent Outlet
and Combustion Air-Inlet of two (2) Slant/Fin
CHS 300-399 boilers.

(Models CHS 300-399 Common Venting Shown Exhaust Gas and

Combustion Air-Inlet piping being directed to the LEFT)



818 193

Common Venting for the Exhaust Vent Outlet
and Combustion Air-Inlet of three (3) Slant/Fin
CHS 300-399 boilers.

(Models CHS 300-399 Common Venting Shown Exhaust Gas and

Combustion Air-Inlet piping being directed to the RIGHT)


Failure to match the appropriate CHS 300-399 Common Venting with the appropriate
boilers, as indicated in Table 2-1, may result in boiler or vent system malfunctions
leading to property damage, serious injury, or death.

Inspection

Prior to the installation of the CHS 300-399 Common Venting, conduct a visual inspection of each vent
component to ensure the parts were not damaged during shipping and were shipped complete.

Do not install broken or damaged venting components; doing so may result in property
damage, serious injury, or death.