EUTECTIC EC-10

18

BURNER DATA—BECKETT BURNERS FOR PACKAGED BOILERS ONLY

† Air shutter and head settings shown are approximate ONLY. See “START-UP” on page 8.

NOTES:
(1) Use 2 Slot air band for all models.
(2) See “PRECAUTIONS BEFORE STARTING OIL BURNERS” and “START-UP” on page 8 and burner figures on this page.
(3) All burner models shown are single stage.
(4) EC-13 and EC-14 are supplied with low fire baffle (Beckett # 5880) installed. Remove it when using .90 GPH.
(5) Use 3-3/8" U static disc for EC-13 and EC-14. Use 2-3/4" U for EC-15 an EC-16.

EMBOSSED AIR BAND ADJUSTMENT
OPENS WHEN ROTATED CLOCKWISE
EXAMPLE: SHOWN AT
N

°

2 POSITION

SEE TABLE FOR CORRECT SETTINGS

SHUTTER ADJUSTMENT SHUTTER
OPENS WHEN ROTATED CLOCKWISE
EXAMPLE: SHOWN AT N

°

6 POSITION

AIR BAND
ADJUSTMENT
SCREW

OIL

PUMP

Boiler

Model

Burner

Model

Blast

Tube

Firing

Rate

GPH

Nozzles

Oil Pump

(PSIG)

Approx.

Head

Setting †

Approx.

Air Shutter

Setting †

Approx.

Air Band

Setting

Size

GPH

Angle &

Type

MFR.

EC-13

AFG(MB)

L2

0.65

0.5

60˚AS

Danfoss

170

n/a

# 9

Closed

0.7

0.5

60˚AS

Danfoss

195

n/a

# 10

Closed

0.65

0.5

60˚ W

Delavan

170

n/a

# 9

Closed

0.7

0.5

60˚ W

Delavan

195

n/a

# 10

Closed

EC-14

AFG(MB)

L2

0.8

0.65

60˚ W

Delavan

150

n/a

# 10

# 3

0.9

0.75

60˚ W

Delavan

145

n/a

# 8.5

Closed

EC-15

AFG(MB)

L1

1

0.75

60˚ B

Delavan

178

n/a

# 10

# 1

1.1

0.85

60˚ B

Delavan

168

n/a

# 10

# 3

EC-16

AFG(MB)

V1

1.15

0.85

60˚ W

Delavan

185

# 0

# 9

Closed

1.15

0.85

60˚ B

Hago

185

# 0

# 9

Closed

Figure 7.

Figure 8.

It is suggested that due to the positive pressure observed in the chamber that the air tube hole and any other passages of the flue gas
leakages be sealed to avoid combustion gas fumes from leaking into the boiler room.