Tie Down Vector Dynamics Foundation System for Wind Zones lll User Manual

Page 14

Advertising
background image

Example of a Single Section 14' x 72' Home

WIND ZONE I for Single Section Homes

Using Vector Dynamics Foundation Systems

Soil Classifications:

2, 3, 4A & 4B

Soil Bearing Capacity:

1,000 PSF Minimum

Anchors Required:

30" with 2-4" helix anchors (#59095) & 12" Stabilizer Plates (#59292)

with 1-1/4" Frame Ties

Home Length

Vector Systems

Anchors Required

24+” Piers

Longitudinal

Required

Per Side Up To 24” Pier

Systems* (LSD)

0 to 72’

3

2

3

1 (2 Struts)

73’ to 90’

4

3

4

1 (2 Struts)

Vector Systems

Longitudinal

(LSD)

Longitudinal

(LSD)

Anchors & Stabilizers

Wind Zone I

NOTES:

Vector Systems should be spaced as symmetrical as possible along the
length of the home. Pier spacing must be consistent with home
manufacturers instruction and/or state requirements.

Maximum allowable working load for metal strut: 3150 lbs.

* One Longitudinal Vector System is made up of 2 struts,

which can be used separately.

D103

0

Tie Down Engineering

255 Villanova Drive SW

Atlanta, Georgia 30336

(404) 344-0000 • Fax (404) 349-0401

www.tiedown.com

14

Revised: 8/19/08