Tie Down Vector Dynamics Foundation System for Wind Zones lll User Manual

Page 23

Advertising
background image

D103

0

Tie Down Engineering

255 Villanova Drive SW

Atlanta, Georgia 30336

(404) 344-0000 • Fax (404) 349-0401

www.tiedown.com

Example of a Triple Section 32' x 72' Home

WIND ZONE III for Triple Section Homes

Using Vector Dynamics Foundation Systems

Soil Classifications:

2, 3, 4A & 4B

Soil Bearing Capacity: 1,000 PSF Minimum

Anchors Required*:

30” with 2-4” helix anchors (#59095) with 1-1/4” vertical ties

(*Marriage wall and sheer wall anchors may be required by home manufacturer.)

Home Length

Vector Systems Anchors Required

Longitudinal

Required

Per Side

System

1

(LSD)

0 to 48'

3 + 2 on Tag

5

3 (6 Struts)

49' to 60'

4 + 2 on Tag

6

3 (6 Struts)

61' to 72'

5 + 2 on Tag

7

3 (6 Struts)

73' to 84'

6 + 2 on Tag

8

3 (6 Struts)

85’ to 90’

7 + 2 on Tag

9

3 (6 Struts)

NOTES:
Vector Systems should be spaced as symmetrical as possible along the length of the home. Pier spacing
must be consistent with home manufacturers instruction and/or state requirements.

Maximum allowable working load for metal strut: 3150 lbs.

1

One Longitudinal Vector System is made up of 2 struts, which can be used separately.

Vector Systems

LSD

LSD

LSD

LSD

LSD

Tag or Full Triple

Vertical Anchors

23

Revised: 8/19/08