Tie Down Vector Dynamics Foundation System for Wind Zones lll User Manual

Page 15

Advertising
background image

D1030

Tie Down Engineering

255 Villanova Drive SW

Atlanta, Georgia 30336

(404) 344-0000 • Fax (404) 349-0401

www.tiedown.com

Example of a Double Section 28' x 72' Home

Vector System

Longitudinal (LSD)

Longitudinal (LSD)

Vector Systems

Vector System

Wind Zone I

WIND ZONE I for Double Section Homes

Using Vector Dynamics Foundation Systems

Soil Classifications:

2, 3, 4A & 4B

Soil Bearing Capacity:

1,000 PSF Minimum

Anchors Required:

None (*Marriage wall and sheer wall anchors may be required by home manufacturer)

Home Length

Vector Systems

Anchors Required

Longitudinal

Required

Per Side

Systems

1

(LSD)

0 to 48’

2

0*

1 (2 Struts)

49’ to 71’

3

0*

1 (2 Struts)

72’ to 84’

4

0*

1 (2 Struts)

85’ to 90’

5

0*

1 (2 Struts)

NOTES:
*No anchors required for pier heights up to 46” for 28’-36’ wide,
38” for 24’ wide. When a pier height at the Vector location is
exceeded, an anchor must be installed outside that location, and
1 longitudinal Vector System added per house.

Vector Systems should be spaced as symmetrical as possible along
the length of the home. Pier spacing must be consistent with home
manufacturers instruction and/or state requirements.

Maximum allowable working load for metal strut: 3150 lbs.

1

One Longitudinal Vector System is made up of 2 struts, which

can be used separately.

15

Revised: 8/19/08