Toa C-RM700 User Manual

Page 35

Advertising
background image

35

7.4.10. I/O speed

Sets each control terminal's transfer rate.

1. Press the Menu key for 3 seconds or more to display the menu

screen.

2. Tilt the joystick up or down to select "I/O SPEED," then press the

SET key to confirm the selection.
The screen for selecting the control terminal is displayed.

3. Tilt the joystick left or right to select "CAMERA," "SWCHER"

(switcher), "REMOTE," or "ALARM," then press the SET key to
confirm the selected control terminal.
The transfer rate is shown on Line 2. In this event, the previously
made setting is displayed.

4. Tilt the joystick left or right to select "4800," "9600," "19200," or

"38400," then press the SET key to confirm the selected transfer
rate.

Note
Set the same transfer rate as those of equipment connected to
each control terminal.

5. To further set other control terminals, repeat Steps 3-4.

To return to the setting item display, press the Clear key.

I / O

S P E E D

I / O

S P E E D

R E M O T E

I / O

S P E E D

R I M O T E

1 9 2 0 0

SET

2

3

SET

4

SET

Control Terminal

Factory Setting

Camera

38400 bps

Switcher

19200 bps

Remote controller

19200 bps

Alarm

38400 bps