49

Remote controller
C-RM700

Alarm Input Unit
C-AL80

ALARM/ / REMOTE IN

RS-232C

Sensor

Alarm input terminal

RS-232C

RS-232C reverse cable
Female D-sub 9-pin connector
to Female D-sub 9-pin connector

8.3. Connection to the Alarm Unit

Note: Select "1. ON" in the Sensor Alarm setting (Refer to

p. 38

,

"Sensor alarm".)

8.4. Connection when Controlling the System from 2 Locations

By connecting 2 C-RM700 Remote Controllers, the system can be controlled from 2 locations.

Set the operation mode of one controller for "MASTER," and the other controller for "SLAVE." (Refer to

p. 29

,

"Operation mode".)

Note
Set the "I/O SPEED: REMOTE" of the MASTER
designated C-RM700 Controller (this unit) and "I/O
SPEED: SWITCHER" of the SLAVE-designated C-
RM700 Controller to the same transfer rate. (Refer
to

p. 35

"I/O speed.")

Shielded twisted-pair cable

Slave unit remote

control terminals

GND

C-RM700 (Operation mode: Master)

C-RM700 (Operation mode: Slave)

Switcher control terminals

GND

I/O SPEED: REMOTE

19200 bps

C-RM700 (Master)

I/O SPEED: SWITCHER

19200 bps

C-RM700 (Slave)

(Example)