16

To Set the Needle Bar at the Correct Height

See that the needle Is pushed up into the needle bar as far

as It will go, then remove the face plate.

The

needle

bar,

which is in the machine
when shipped from the

factory, has two timing

marks near its upper
end. Rotate the bal­
ance whee1 unt i1 the

needle bar moves down

to its lowest position.
The UPPER TIMING MARK
on

the

needle

bar

should then be centered

with the lower end of

the needle bar bushing,

as shown at (D) in Fig.
20. In case the needle

bar is not set at the

correct

height,

loosen

screw

(E,Flg.20)

and

move the needle bar up

or down until the UPPER

TIMING MARK is centered

with the lower end of

the needle bar bushing,

as shown at (D,Fig.20),

then

securely

tighten

screw (E).

In the event that

the

setting

of

the

needle bar bushing has

been disturbed, thus making it impossible to set the needle bar
for correct height by centering the upper timing mark with the

lower end of the needle bar bushing, turn the balance wheel to

bring the hook point to the center of the needle, loosen screw

(E) and move the needle bar up or down to bring the top of the

needle eye 1/32 inch below the point of the hook, then securely

tighten screw (E). Loosen the needle bar bushing set screw at
the top of the machine arm and, while the hook point is at the

center of the needle and 1/32 inch above the top of the needle
eye, move the needle bar bushing up or down to bring its lower

end exactly even with the LOVER TIMING MARK on the needle bar,

then securely tighten the needle bar, bushing set screw.

Fig.20

Needle Bar Set at Correct Height