22

To Adjust the Thread Take-up Spring

The thread take-up spring (Ci2,Flg.26) should be set so that

when the eye of the needle reaches the goods on the downward

Fig.26. Adjustment of Thread Take-up Spring

stroke of the needle bar, the spring will be through acting and

will rest against the stop on-the thread take-up spring regulator.

If the thread take-up spring Is not correctly set, as Instructed

above, loosen the set screw (R2,Flg.26) In the arm of the machine,
and turn the tension stud (S2,Flg.26) to the right for more move­
ment of the spring or to the left for less movement. When the

spring Is-correctly set, securely tighten the set screw (R2).

The tension on the thread take-up spring (Q2) Is regulated

by turning the tension stud (S2) to the right to Increase the

tension, or to the left to decrease the tension. The tension on
the thread take-up spring should be just sufficient to take up
the Slack of^the needle thread until the eye of the needle

reaches the goods In Its descent.

Timing of the Feeding Mechanism

When the machine leaves the factory, the feed eccentric Is

correctly set by having the timing screw In the eccentric enter

the groove In the arm shaft. If, for any reason. It may be nec­

essary to alter the timing of the feed eccentric, loosen the

timing screw and the set screw, turn the eccentric as required

tighten the set screw only.