How to replace stationary knife, How to exchange light bulb, How to adjust presser foot pressure – SINGER 14U236B User Manual

Page 35

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

25.

How to replace stationary knife

The stationary knife (available from your Singer Dealer) should be changed when it becomes dull.

The stationary knife can be replaced according to the following steps, however if there are any difficulties
experienced, call your Singer representative to make the adjustment.

(1) Be sure that the power line plug is disconnected from

the wall receptacle.

(2) Open the looper cover and set the movable knife in the

non-operating position (see page 21).

(3) Loosen the stationary knife set screw and remove the

stationary knife.

(4) Place a new stationary knife in the groove of the

stationary knife holder, align the cutting edge level
with the top surface of the throat plate and tighten set
screw.

(5) Return the movable knife to its original position.

26.

How to exchange light bulb

Light bulb (available from your Singer Dealer) is a
bayonet type 12 volt, 6 watt bulb.

Disconnect power-line plug.

Remove light cover as shown in figure, turn bulb to
left and remove. To replace, push bulb into socket
and turn to right.

27.

How to adjust presser foot pressure

Pressure regulating thumb screw

The presser foot pressure of this machine is
preadjusted at the factory to suit the sewing of
medium weight fabrics.

It may become necessary to adjust the pressure

in the case of delicate or heavy weight fabric.

For light weight fabric — Decrease the pressure

(as shown at left).

Heavy weight fabric — Increase the pressure
(as shown at left).