Matrix-2000™ connector electrical connections, Db25-pin connector – Datalogic Scanning Compact 2D Reader Matrix-2000 User Manual

Page 53

Advertising
background image

19-PIN CONNECTOR ELECTRICAL CONNECTIONS

5

5 MATRIX-2000™ CONNECTOR ELECTRICAL CONNECTIONS


5.1 DB25-PIN CONNECTOR


The Matrix-2000

™ reader is equipped with a 25-pin male D-Sub connector for connection to

the power supply and input/output signals. The details of the connector pins are indicated in
the following table:

13

25

14

1

Figure 61 - 25-pin male D-Sub Connector

19-pin M16 male connector pinout

Pin Name

Function

9, 13

Vdc

Power supply input voltage +

23, 25

GND

Power supply input voltage -

1 CHASSIS

Cable shield internally connected by capacitor to the
chassis

18

I1A

External Trigger A (polarity insensitive)

19

I1B

External Trigger B (polarity insensitive)

6

I2A

Input 2 A (polarity insensitive)

10

I2B

Input 2 B (polarity insensitive)

8

O1+

Output 1 +

22

O1-

Output 1 -

11

O2+

Output 2 +

12

O2-

Output 2 -

16

O3+

Output 3 +

17

O3-

Output 3 -

20

RX

Auxiliary RS232 RX (referred to GND)

21

TX

Auxiliary RS232 TX (referred to GND)

14, 15, 24

NC

Not connected

Pin Name RS232

RS485

Full-Duplex

RS485

Half-Duplex

2 TX

TX+

RTX+

3 RX

*RX+

4 RTS

TX-

RTX-

5

MAIN

INTERFACE

(SW

SELECTABLE)

CTS

*RX-

7

GND_ISO GND_ISO

GND_ISO


* Do not leave floating, see par. 5.5.2 for connection details.


In order to meet EMC requirements:

connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;

connect the main interface cable shield to pin 1 of the 25-pin connector;

use two clip-on ferrite sleeves (type Stewart 28A2029-0A0 or equivalent) on the main
interface cable near the reader 25-pin connector;

connect the Ethernet interface cable shield to reader chassis (for Matrix-21XX only)

43

Advertising