19-PIN CONNECTOR ELECTRICAL CONNECTIONS

5

5.5.2 RS485

Full-Duplex

Interface


The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication
protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft) than
those acceptable for RS232 communications or in electrically noisy environments.

The following pins of the 25-pin connector are used for RS485 full-duplex communication:

Pin Name

Function

2

TX+

RS485 Transmit Data (+)

4

TX-

RS485 Transmit Data (-)

3

RX+

RS485 Receive Data (+)

5

RX-

RS485 Receive Data (-)

7

GND_ISO

Main opto-isolated reference ground


MATRIX

GND_ISO

RX+

RX-

TX-

TX+

USER INTERFACE

TX485

RX485

SHIELD

Reference Ground

7

3

5

4

2

+

1

-

+

-

Earth Ground

Earth Ground

Chassis

Figure 67 - RS485 Full-duplex Connections



NOTE

For applications that do not use RX485 signals, do not leave these lines
floating but connect them to GND_ISO as shown below.

MATRIX

GND_ISO

RX+

RX-

TX-

TX+

USER INTERFACE

RX485

SHIELD

Reference Ground

7

3

5

4

2

+

1

-

Earth Ground

Earth Ground

Chassis

Figure 68 - RS485 Full-duplex Connections using Only TX Signals