19-PIN CONNECTOR ELECTRICAL CONNECTIONS

5

5.4 POWER SUPPLY


Power is supplied to the reader through the pins provided on the 25-pin connector (see
Figure 64):

MATRIX

9/13

23/25

Vdc

GND

1

SHIELD

USER INTERFACE

CHASSIS

V- (Ground)

V+ (10 - 30 Vdc)

Earth Ground

Earth Ground

Chassis

Figure 64 - Power Supply Connection


The allowed supply voltage range is 10 to 30 Vdc.

5.5 MAIN SERIAL INTERFACE


The signals relative to the following serial interface types are available on the 25-pin
connector.

The main serial interface type and its parameters (baud rate, data bits, etc.) can be
defined by the user via VisiSet™ software. The RS485 half duplex is automatically set
whenever MUX32 communication protocol is enabled. For more details refer to the
"Communication" folder in the VisiSet™ Help On Line.

Details regarding the connections and use of the interfaces are given in the next paragraphs.

5.5.1 RS232

Interface


The opto-isolated RS232 interface can be used for Point-to-Point, Pass Through or
Master/Slave connections. When it is connected to the host computer it allows both
transmission of code data and reader configuration by VisiSet™.

The following pins of the 25-pin connector are used for RS232 interface connection:

Pin Name

Function

2 TX

Transmit

Data

3 RX

Receive

Data

4

RTS

Request To Send

5

CTS

Clear To Send

7

GND_ISO

Main opto-isolated reference ground



It is always advisable to use shielded cables. The overall maximum cable length must be
less than 15 m (49.2 ft).