19-PIN CONNECTOR ELECTRICAL CONNECTIONS

5

INPUT 2 CONNECTIONS USING EXTERNAL POWER

Matrix-2000™

INPUT DEVICE

Vext 30 Vdc max.

6

10

V

CC

~

~

+

-

V

Signal

I2A

I2B

I

in

Figure 82 - Input PNP Using External Power



Matrix-2000™

INPUT DEVICE

Vext 30 Vdc max.

6

10

Signal

V

V

CC

~

~

+

-

I2A

I2B

Figure 83 - Input NPN Using External Power


5.9 OUTPUTS


Three opto-coupled general purpose outputs are available on the 25-pin connector. The
meaning of the three outputs can be defined by the user. They are typically used either to
signal the data collection result or to control an external lighting system.

The pinout is the following:

Pin Name Function

8

O1+

Configurable digital output 1 - positive pin

22

O1-

Configurable digital output 1 - negative pin

11

O2+

Configurable digital output 2 - positive pin

12

O2-

Configurable digital output 2 - negative pin

16

O3+

Configurable digital output 3 - positive pin

17

O3-

Configurable digital output 3 - negative pin



The electrical features of the three outputs are the following:

OUTPUT I

Load

V

Out

Open

0 mA

30 Vdc Max

Closed

10 mA

1.8 Vdc Max

P

D

= V

Out

× I

oLoad

= 170 mW Max.



By default, Output 1 is associated with the Partial Read and No Read events, which activates
when the code(s) signaled by the external trigger are not decoded, and Output 2 is
associated with the Complete Read event, which activates when all the selected codes are
correctly decoded. Output 3, by default, is not associated with any event.

55