Datalogic Scanning Compact 2D Reader Matrix-2000 User Manual

Page 99

Advertising
background image

TROUBLESHOOTING

10

TROUBLESHOOTING GUIDE

Problem Suggestion
One Shot or Phase Mode
using serial trigger source:
the ”TRIGGER” LED is not
blinking.

•

In the Operating Mode folder check the settings for
Reading Phase-ON, Acquisition Trigger and
Reading Phase-OFF
parameters.

•

Are the COM port parameters (Baud Rate, Parity, Data
Bits, Stop Bits, Handshake
) correctly assigned?

•

In the communication folder, check the settings of
Reading Phase-ON String, Acquisition Trigger
String
and Reading Phase-OFF String parameters.

•

Is the serial trigger source correctly connected?

Phase Mode:
the ”TRIGGER" LED is
correctly blinking but no image
is displayed in VisiSet™
Calibration Tool window.

•

Is the Phase frequency lower than the maximum frame
rate?

Continuous Mode:
the ”TRIGGER” LED is not
blinking.

•

Verify the correct software configuration settings.

Any Operating Mode:
the ”TRIGGER” LED is
correctly blinking but no result
is transmitted by the reader at
the end of the reading phase
collection.

•

In the Data Collection folder check the settings for the
CODE COLLECTION, DATA FORMAT and
STATISTICS parameter groups.

Image not clear:

•

verify the Focus procedure

Image focused but not
decoded:

•

verify the Calibrate Image Density prodcedure.

Reading:
the reader always transmits
the No Read Message

•

Perform the Rapid Configuration procedure in chapter 1.

•

Position the reader as described in par. 3.3, par. 7.1
and through the VisiSet™ Calibration Tool:
− Tune the ACQUISITION TRIGGER DELAY, if the

moving code is out of the reader field of view;

− Set the Continuous Operating Mode if no external

trigger source is available;

− Tune the IMAGE ACQUISITION SETTING to

improve the code image quality;

− Check the parameter setting in Decoding,

2D Codes, 1D Codes, and Postal Codes folders;

− View the full resolution code image to check the

printing or marking quality.

Communication:
reader is not transmitting
anything to the host.

•

Is the serial cable wiring correct?

•

If using CBX, be sure the RS485 termination switch is
OFF.

•

Are the host serial port settings the same as the reader
serial port settings?

•

In VisiSet™ Digital I/O folder, "COM" LED can be
configured to indicate MAIN COM port TX or MAIN
COM port RX.

Communication:
data transferred to the host

•

Are the host serial port settings the same as the reader
serial port settings?

89