Installation – Desa EFS33NR User Manual

Page 10

Advertising
background image

www.desatech.com

107172-01K

10

*

INSTALLATION

Continued

INSTALLATION CLEARANCES

WARNING: Maintain the

minimum clearances. If you

can, provide greater clearances

from floor, ceiling and adjoining

wall.

Carefully follow the instructions below. This will

ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 8.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 8).

B. Clearances from the top of the fireplace open-

ing to the ceiling should not be less than 42

inches.

*Minimum 16 inches from Side Wall

Example

Figure 8 - Minimum Clearance for

Combustible to Wall

CONVENTIONAL FIREPLACE
INSTALLATION

Conventional installation of this fireplace involves

installing fireplace along with the corner, face or

cabinet mantel with hearth base accessories against

a wall in your home. Follow the instructions in

this section to install the fireplace in this manner.
Note:

The instructions in this section show instal-

lation using the cabinet mantel and the GC3333F/

GC3334U/G3004W/GC3335F/G3007U series

hearth base accessories. The hearth base accessory

shown is optional for this installation. You can

install fireplace and cabinet/corner mantel directly

on the floor. The corner mantel accessory cannot be

installed with the GC3333F/GC3334U/G3004W/

GC3335F/G3007U hearth base. The corner mantel

can be paired with the G3008F/G3009U/G3010F

corner hearth base. If mounting fireplace and cabinet

or corner mantel to the floor, an optional G3005J/

3005S/3005B Slim Base kit may be installed.
1. Assemble cabinet mantel, hearth base and

trim accessories. Assembly instructions are

included with each accessory.

2. When installing blower, install a properly

grounded, 120 volt three-prong electrical out-

let at fireplace location if an outlet is not there.

If possible, locate outlet so cabinet mantel will

cover it when installed (see Figure 9).

3. Install gas piping to fireplace location. This in-

stallation includes an approved flexible gas line

(if allowed by local codes) after the equipment

shutoff valve. The flexible gas line must be the

last item installed on the gas piping. See Install-

ing Gas Piping to Fireplace Location, page 13.

4. Place hearth base accessory against wall at instal-

lation location. Cut an access hole in hearth top

to run flexible gas line to fireplace (see Figure

9). Make sure to locate access hole so cabinet

mantel will cover it when installed. Note: You

can secure base to floor using wood screws.

Countersink screw heads and putty over.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

Right Sides

and Rear

0"

16"

0"

*

Figure 9 - Placing Hearth Base

Accessory Against Wall