Installation – Desa EFS33NR User Manual

Page 13

Advertising
background image

www.desatech.com

107172-01K

13

INSTALLATION

Continued

13"

16"

19"

21"

2

1

/

2

"

6"

8"

10"

Minimum Non-
Combustible
Material

Figure 16 - Minimum Mantel Clearances

for Built-In Installation

Mantel Shelf

Note: All vertical
measurements
are from top
of fireplace
opening to
bottom of
mantel shelf.

INSTALLING GAS PIPING TO
FIREPLACE LOCATION

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: Never connect pro-

pane/LP fireplace directly to the

propane/LP supply. This fireplace

requires an external regulator

(not supplied). Install the external

regulator between the fireplace

and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

Installation Items Needed
Before installing fireplace, make sure you have

the items listed below.
• external regulator for propane/LP unit only

(supplied by installer)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap (optional)
• tee joint
• pipe wrench
• approved flexible gas line with gas connector

(if allowed by local codes) (not provided)

* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 34.
For propane/LP units, the installer must supply

an external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down

as shown in Figure 17. Pointing the vent down

protects it from freezing rain or sleet.

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to fireplace.

If pipe is too small, undue loss

of volume will occur.

Figure 17 - External Regulator with Vent

Pointing Down

External
Regulator

Vent
Pointing
Down

Propane/LP
Supply Tank

Advertising
This manual is related to the following products: