16

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 21).
2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

3. Check all joints from gas meter to equipment

shutoff valve for natural gas or propane/LP sup-

ply to equipment shutoff valve for propane/LP

(see Figures 22 and 23). Apply noncorrosive

leak detection fluid to all joints. Bubbles form-

ing show a leak.

4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 21).
2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Make sure control knob of fireplace is in the

OFF position.

4. Check all joints from equipment shutoff valve

to gas control valve (see Figures 22 or 23).

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light fireplace (see Operating Fireplace, page

19. Check all other internal joints for leaks.

7. Turn off fireplace (see To Turn Off Gas to

Appliance, page 20).

INSTALLATION

Continued

Figure 21 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff Valve

Figure 23 - Checking Gas Joints for

Propane/LP Gas

Propane/LP
Supply Tank

Equipment
Shutoff
Valve

Gas Control Valve

Gas Meter

Figure 22 - Checking Gas Joints for

Natural Gas

Gas Control Valve

Equipment Shutoff Valve

INSTALLING LOGS (MODELS
EFS33NR, EFS33PR, VSGF33NR
AND VSGF33PR)

WARNING: Failure to posi-

tion the parts in accordance

with these diagrams or failure

to use only parts specifically

approved with this heater may

result in property damage or

personal injury.

CAUTION: Do not remove the

metal data plates attached to the

heater base assembly. The data

plates contain important safety

and warranty information.

It is very important to install these logs exactly

as instructed. Do not modify logs. Only use logs

supplied with heater.