Installation, Air for combustion and ventilation – Desa EFS33NR User Manual

Page 8

Advertising
background image

www.desatech.com

107172-01K

8

INSTALLATION

NOTICE: This heater is intended

for use as supplemental heat.

Use this heater along with your

primary heating system. Do not

install this heater as your pri-

mary heat source. If you have a

central heating system, you may

run system’s circulating blower

while using heater. This will help

circulate the heat throughout the

house. In the event of a power

outage, you can use this heater

as your primary heat source.

WARNING: A qualified ser-

vice person must install heater.

Follow all local codes.

WARNING: Never install the

fireplace

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture, cloth-

ing or other flammable objects

are less than 42 inches from the

front, top or sides of the heater

• in high traffic areas

• in windy or drafty areas

CAUTION: This heater cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to heater. Installing

heater next to vinyl or cloth wall

coverings or operating heater

where impurities (such as, but

not limited to, tobacco smoke,

aromatic candles, cleaning flu-

ids, oil or kerosene lamps, etc.) in

the air exist, may discolor walls

or cause odors.

Note:

Your fireplace is designed to be used in zero

clearance installations. Wall or framing material

can be placed directly against any exterior surface

on the rear, sides or top of your fireplace, except

where standoff spacers are integrally attached. If

standoff spacers are attached to your fireplace,

these spacers can be placed directly against wall

or framing materials.
Use the dimensions shown for rough openings to

create the easiest installation. See Built-In Fire-

place Installation, page 11.
IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing fire-

place in rooms without enough ventilation air may

cause mildew to form from too much moisture.

See Air for Combustion and Ventilation, pages 6.
IMPORTANT:

Make sure the fireplace is level.

If fireplace is not level, log set will not work

properly.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP)

for your fireplace. If your gas supply is not cor-

rect, do not install fireplace. Call dealer where you

bought fireplace for proper type fireplace.

Figure 4 - Ventilation Air from Outdoors

Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or

ducts. You must provide two permanent openings:

one within 12" of the ceiling and one within 12"

of the floor. Connect these items directly to the

outdoors or spaces open to the outdoors. These

spaces include attics and crawl spaces. Follow the

National Fuel Gas Code, ANSI Z223.1/NFPA 54,

Section 5.3, Air for Combustion and Ventilation for

required size of ventilation grills or ducts.
IMPORTANT:

Do not provide openings for inlet

or outlet air into attic if attic has a thermostat-

controlled power vent. Heated air entering the attic

will activate the power vent.

AIR FOR COMBUSTION

AND VENTILATION

Continued

Outlet

Air

Ventilated

Attic

Outlet

Air

Inlet

Air

Inlet Air

Ventilated

Crawl Space

To

Crawl

Space

To Attic

Advertising
This manual is related to the following products: