Installation – Desa EFS33NR User Manual

Page 12

Advertising
background image

www.desatech.com

107172-01K

12

INSTALLATION

Continued

1. Frame in rough opening. Use dimensions

shown in Figure 13 for the rough opening. If

installing in a corner, use dimensions shown

in Figure 14 for the rough opening. The height

is 33" which is the same as the wall opening

above.

2. If using blower, install and properly ground

GA3555, three-prong 120 volt electrical out-

let, in fireplace. Follow instructions included

in kit.

3. Install gas piping into fireplace location. This

installation includes an approved flexible gas

line (if allowed by local codes) after the equip-

ment shutoff valve. The flexible gas line must

be the last item installed on the gas piping. See

Installing Gas Piping to Fireplace Location,

page 13.

4. Carefully set fireplace in front of rough opening

with back of fireplace inside wall opening.

5. Carefully insert fireplace into rough opening.
6. Attach flexible gas line to gas supply. See Con-

necting Fireplace to Gas Supply, page 14.

7. Attach fireplace to wall studs using nails or

wood screws through holes in nailing flange

(see Figure 15).

8. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

9. Plug electrical cord into electrical outlet

installed in step 2.

10. Install brass trim after final finishing and/or

painting of wall (see Figure 7, page 9).

Figure 13 - Rough Opening for Installing

in Wall

Figure 14 - Rough Opening for Installing

in Corner

Figure 15 - Attaching Fireplace to Wall

Studs

35

1

/

2

"

17

3

/

4

"

33"

39

3

/

8

"

27

7

/

8

"

55

5

/

8

"

35

1

/

2

"

Nailing Flanges

Nails or
Wood
Screws

Mantel Clearances for Built-In
Installation
If placing mantel above built-in fireplace, you must

meet minimum clearance between mantel shelf and

top of fireplace opening.

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• raise the mantel to an accept-

able height

• remove the mantel

NOTICE: Surface temperatures

of adjacent walls and mantels

become hot during operation.

Walls and mantels above the

firebox may become hot to

the touch. If installed properly,

these temperatures meet the

requirement of the national

product standard. Follow all

minimum clearances shown in

this manual.

Advertising