Installation – Desa EFS33NR User Manual

Page 15

Advertising
background image

www.desatech.com

107172-01K

15

INSTALLATION

Continued

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply a noncorrosive leak detec-

tion fluid to all joints. Bubbles

forming show a leak. Correct all

leaks at once.

CAUTION: Make sure exter-

nal regulator has been installed

between propane/LP supply and

fireplace. See guidelines under

Connecting Fireplace to Gas

Supply, page 14.

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect fireplace with its main gas valve

(control valve) and equipment shutoff valve

from gas supply piping system. Pressures

in excess of 1/2 psig will damage fireplace

regulator.

2. Cap off open end of gas pipe where equipment

shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

4. Check all joints of gas supply piping system.

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect fireplace and equipment shutoff

valve to gas supply. Check reconnected fittings

for leaks.

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 20).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

4. Attach the flexible gas line to gas supply (see

Figure 20). Check tightness of flexible gas

line attached to gas regulator of fireplace (see

Figure 20).

5. Check all gas connections for leaks. See

Checking Gas Connections.

6. Replace log base assembly back into fireplace.

Feed flexible gas line into fireplace base area

while replacing log base assembly. Make sure

the entire flexible gas line is in fireplace base

area. Reattach log base assembly to fireplace

with screws removed in step 2, page 14.

Figure 20 - Attaching Flexible Gas Lines

Together

Flexible Gas Line from
Fireplace Gas Regulator

To Fireplace
Gas Regulator

Equipment Shutoff Valve
Provided by Installer

Propane/LP
To External Regulator
Natural Gas
To Gas Meter

Advertising
This manual is related to the following products: