LOCAL CODES

Install and use heater with care. Follow all local

codes. In the absence of local codes, use the lat-

est edition of The National Fuel Gas Code ANSI

Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note:

Where listed vented decorative logs are

required, thermostat operation is not permitted.

UNPACKING

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

1. With utility knife, cut the carton all the way

around above the staples on the bottom tray.

Lift the carton off the heater. Remove packing.

Note:

The hood is located in the packing on

the right hand side of the heater front. Lift the

heater off the bottom tray.

2. Locate two screws above top corners of the

fireplace screen. Remove and discard these

screws. Lift fireplace screen up and pull out

to remove.

3. Remove protective packaging applied to logs,

log base assembly and fireplace.

4. Remove fireplace hood from carton insert.
5. Check all items for any shipping damage. If

damaged, promptly inform dealer where you

bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires

no outside venting. There is no heat loss out a

vent or up a chimney. Heat is generated by both

realistic flames and glowing embers. When used

without the optional blower, the fireplace requires

no electricity making it ideal for emergency

backup heat.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Depletion

Sensing (ODS) safety shutoff system. The ODS/

pilot is a required feature for vent-free room heat-

ers. The ODS/pilot system shuts off the fireplace

if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system

requires no matches, batteries or other sources to

light fireplace.

OPTIONAL REMOTE CONTROL
ACCESSORY

There are four optional remote controls (not

included) that can be purchased separately for

this log heater:
• wall switch
• wall thermostat
• hand-held ON/OFF remote
• hand-held thermostat remote
See Accessories, page 34.

OPTIONAL BLOWER ASSEMBLY
ACCESSORY

This fireplace accepts an optional blower assembly

(not included). The GA3700TA Series blower

operates thermostatically and features a variable

speed control. The GA3700 Series operates manu-

ally and also features a variable speed control. The

blower circulates heated air from the fireplace into

the room. Use of blower is optional. See Acces-

sories, page 34.