Installation
• 11
2.4 Base Address Setting
The ACL-8111 requires 16 consecutive address locations in I/O address 
space. The base address of the ACL-8111 is restricted by the following 
conditions. 
1. The base address must be within the range Hex 200 to Hex 3FF.
2. The base address should not conflict with any PC reserved I/O address.
See Appendix A.
3. The base address must not conflict with any add-on card on your own
PC. Please check your PC before installing the ACL-8111.
The ACL-8111's base address is selected by a 6 position DIP switch 
SW1.The default setting of base address is set to be HEX 220. All possible 
base address combinations are listed as Table 2.2. You may modify the 
base address if the address HEX 220 has been occupied by another add-on 
card. 
SW 1 : Base Address = Hex 220
1
2
3
4
5
6
O N
DIP
A ( 9 8 7 6 5 4 )
Figure 2.4 Default Base Address Setting