8 digital i/o register, 9 d/a output register – ADLINK ACL-8111 User Manual
Page 30
 
24
• Registers Format
3.8 Digital I/O register
There are 16 digital input channels and 16 digital output channels are 
provided by the ACL-8111. The address Base + 6 and Base + 7 are used for 
digital input channels, and the address Base + 13 and Base + 14 are used for 
digital output channels. 
 
Address : BASE + 6 & BASE + 7 
Attribute: read only 
Data Format:
Bit
7
6
5
4
3
2
1
0
Base + 6
DI7
DI6
DI5
DI4 DI3 DI2 DI1 DI0
Base + 7
DI15 DI14 DI13 DI12 DI11 DI10 DI9 DI8
Address: BASE + 13 & BASE + 14 
Attribute: write only 
Data Format:
Bit
7
6
5
4
3
2
1
0
Base + 13
DO7 DO6 DO5 DO4 DO3 DO2 DO1
DO0
Base + 14
DO15 DO14 DO13 DO12 DO11 DO10 DO9 DO8
3.9 D/A
Output
Register
The D/A converter will convert the D/A output register data to the analog 
signal. The register data of the address Base + 4 and Base + 5 are used for 
D/A conversion. 
 
Address: BASE + 4 & BASE + 5 
Attribute: write only
Data Format:
Bit
7
6
5
4
3
2
1
0
Base + 4
DA7 DA6 DA5 DA4 DA3
DA2
DA1 DA0
Base + 5
X
X
X
X
DA11 DA10 DA9 DA8
 
DA0 is the LSB and DA11 is the MSB of the 12 bit data. 
X: don't care