4.1.3 A/D Data Transfer Modes
On the ACL-8111, three A/D data transfer modes can be used when the 
conversion is completed. The data transfer mode is controlled by the mode 
control register (BASE+11). The different transfer modes are specified as 
follows: 
Software Data Transfer
Usually, this mode is used with software A/D trigger mode. After the A/D 
conversion is triggered by software, the software should poll the DRDY bit 
until it becomes to high level. Whenever the low byte of A/D data is read, the 
DRDY bit will be cleared to indicate the data is read out. 
It is possible to read A/D converted data without polling. The A/D conversion 
time will not excess 8µs on ACL-8111 card. Hence, after software trigger, the 
software can wait for at least 25µs then read the A/D register without polling. 
EOC Interrupt Transfer
The ACL-8111 provides hardware interrupt capability. Under this mode, an 
interrupt signal is generated at end of A/D conversion (EOC) then the data is 
ready to be read. It is useful to combine the interrupt transfer with the timer 
pacer trigger mode. Under this mode, the data transfer is essentially 
asynchronous with the control software. 
When the interrupt transfer is used, you have to set the interrupt IRQ level by 
hardware jumper. Please refer section 2.10 for IRQ jumper setting. After the 
A/D conversion is completed, a hardware interrupt will be inserted and its 
corresponding ISR (Interrupt Service Routine) will be invoked and executed. 
The converted data is transferred by the ISR program.