System Management

The PXIS-2719A provides advanced remote monitoring and con-
trol of chassis status, including internal temperature, fan speed,
and DC voltages, all exported via a standard RS-232 port, allow-
ing the system to be monitored on a remote computer. The remote
computer can also be used to turn the system on or off through the
monitoring port via software commands.

Remote monitoring and control of the PXIS-2719A requires con-
nection of the remote monitoring port to a remote computer by a
standard RS-232 cable.

ADLINK provides an interface-based program (PXISRemoteMo-
nUtil.exe) to monitor the status of PXIS-2719A via a remote com-
puter. As shown, the utility is divided into three interface
categories:

X

Connect Control

X

Threshold & Control

X

Chassis Status.

NOTE:

NOTE:

The remote monitor port is Rx-Tx/Tx-Rx crossed, requiring a