2 function library, Initcom, Function library – ADLINK PXIS-2719A User Manual

Page 51: Table 4-1: data structure variables

Advertising
background image

Monitoring/Control Functions

41

PXIs-2719A

Table 4-1: Data Structure Variables

4.2

Function Library

InitCOM

Description

Initializes the remote computer COM port connected to the
remote monitoring port of the PXIS-2719A.

Syntax

HANDLE InitCOM(LPCSTR com)

Parameter

com:

A string denotes the COM port. Can be COM1 ~
COM8

Return Value

A handle to the initialized COM port. If the function returns
NULL, the initialization of COM port failed.

Threshold12V_
H

12V High Threshold

int

0.01 Voltage

Threshold12V_
L

12V Low Threshold

int

0.01 Voltage

ThresholdN12V
_H

-12V High Threshold

int

0.01 Voltage

ThresholdNV12
_L

-12V Low Threshold

int

0.01 Voltage

FanFullSpeed

Fan in Full Speed

BYTE

1:Full, 0:Auto

MajorNo

MCU code Version Major
Number

BYTE

Number

MinorNo

MCU code Version Minor
Number

BYTE

Number

Variable

Description

Type

Value