2 input range and data format, 3 adc and analog input filter, Adc (analog-to-digital converter) – ADLINK PXIe-9529 User Manual

Page 25: Input range and data format, Adc and analog input filter

Advertising
background image

Operations

15

PXIe-9529

3.2.2

Input Range and Data Format

When using an A/D converter, properties of the signal to be mea-
sured should be considered prior to selecting channel and signal
connection to the module. A/D acquisition is initiated by a trigger
source, which must be predetermined.Data acquisition com-
mences once the trigger condition is established. Following com-
pletion of A/D conversion, A/D data is buffered in a Data FIFO,
and can then be transferred to PC memory for further processing.

Transfer characteristics of the two input ranges of the PXIe-9529

are as follows. Data format of the PXIe-9529 is 2’s complement.

.

Table 3-1: Input Range and Data Format

Table 3-2: Input Range Midscale Values

3.2.3

ADC and Analog Input Filter

ADC (Analog-to-Digital Converter)

The PXIe-9529 provides sigma-delta analog-to-digital converters,

suitable for vibration, audio, and acoustic measurement. Analog
side of the sigma-delta ADC is 1-bit, and the digital side performs
oversampling, noise shaping and digital filtering. For example, if a
desired sampling rate is 108kS/s, each ADC samples input signals

Description

Full-scale
range

Least
significant
bit

FSR-1LSB

-FSR

Bipolar Analog
Input

±10 V

1.19 μV

9.99999881 V -10 V

±1V

0.119 μV

0.999999881V -1 V

Digital Code

N/A

N/A

7FFFFF

800000

Description

Midscale +1LSB Midscale Midscale –1LSB

Bipolar Analog
Input

1.19 μV

0 V

-1.19 μV

0.119 μV

0 V

-0.119 μV

Digital Code

000001

000000

-FFFFFF

Advertising