2 general purpose digital input (edi), General purpose digital input (edi) – ADLINK EOS-1200 User Manual

Page 35

Advertising
background image

Introduction

23

EOS-1200

1.9.2

General Purpose Digital Input (EDI)

The EOS-1200 provides 16 opto-isolated digital input channels on
the front panel. Circuitry of the isolated input channel is as follows.

As shown, signal connections for a supply and load connected to
an isolated input, here in the EOS-1200, can determine when a
load is powered. The load is connected to the power supply by a
switch and can be any DC voltage between 0 and 24 VDC. When
the switch is open, no current flows through the load and no volt-
age is applied to the load or to the EOS-1200 DI channels.

The digital logic of the EOS-1200 then registers a logic high for the
channel. When the switch is closed, current flows through the
diode and the EOS-1200 registers logic low for the channel.

Photo Coupler

DICOM

DIn

Ri

I

f

Advertising