A.1.5 do_readport, A.1.5, Do_readport – ADLINK EOS-1200 User Manual

Page 65

Advertising
background image

Function Library

53

EOS-1200

Return Code(s)

NoError
ErrorInvalidCardNumber
ErrorCardNotRegistered
ErrorFuncNotSupport
ErrorInvalidIoChannel

A.1.5

DO_ReadPort

Description

Reads back the output digital data from the specified digital
output port.

Syntax

C/C++

I16 DO_ReadPort (U16 CardNumber, U16 Port, U32
*Value)

Visual Basic

DO_ReadPort (ByVal CardNumber As Integer,
ByVal Port As Integer, Value As Long) As Inte-
ger

VB.Net

DO_ReadPort (ByVal CardNumber As Short, ByVal
Port As Short, ByRef Value As Integer) As Short

C#

short DO_ReadPort (ushort CardNumber, ushort
Port, out uint Value)

Parameter(s)

CardNumber

ID of the card for release.

Port

Digital input port number. Valid values: PCMe-1432 0, 1

Value