A.1.6 do_writeport, A.1.6, Do_writeport – ADLINK EOS-1200 User Manual

Page 66

Advertising
background image

54

Function Library

Returns the digital data read from the specified output port.
Valid values: PCMe-1432 16-bit data (for port 0 and port 1)

Return Code(s)

NoError
ErrorInvalidCardNumber
ErrorCardNotRegistered
ErrorFuncNotSupport
ErrorInvalidIoChannel

A.1.6

DO_WritePort

Description

Writes digital data to the specified digital output port.

Syntax

C/C++

I16 DO_WritePort (U16 CardNumber, U16 Port,
U32 Value)

Visual Basic

DO_WritePort (ByVal CardNumber As Integer,
ByVal Port As Integer, ByVal Value As Long) As
Integer

VB.Net

DO_WritePort (ByVal CardNumber As Short, ByVal
Port As Short, ByVal Value As Integer) As Short

C#

short DO_WritePort (ushort CardNumber, ushort
Port, uint Value)

Parameter(s)

CardNumber

ID of the card for release.

Port

Digital input port number. Valid values: PCMe-1432 0, 1